Product Filter
Bussmann LMI Fuse Holder Module- Suits AMI/MIDI Bolt-in Fuses - Connector-Tech ALS
Bussmann LMI Fuse Holder Module- Suits AMI/MIDI Bolt-in Fuses
Bussmann
MPN : LMI-F-M
$14.35
+GST
Bussmann LMI Input Module- use with LMI-F-M AMI/MIDI - Connector-Tech ALS
Bussmann LMI Input Module- use with LMI-F-M AMI/MIDI
Bussmann
MPN : LMI-I-M
$10.87
+GST
ATC/ATO Blade Fuse Holder Inline 1A-40A 12AWG 3.3mm2 - Connector-Tech ALS
ATC/ATO Blade Fuse Holder Inline 1A-40A 12AWG 3.3mm2
Ionnic
MPN : FH16
$5.25
+GST
APX MAXI Blade Fuse Holder 20A-60A 8AWG 8.3mm2 - Connector-Tech ALS
APX MAXI Blade Fuse Holder 20A-60A 8AWG 8.3mm2
Ionnic
MPN : FH17
$12.12
+GST
Bussmann MRBF Marine Fuse Holder 1x 8mm Stud with Cover - Connector-Tech ALS
Bussmann MRBF Marine Fuse Holder 1x 8mm Stud with Cover
Bussmann
MPN : MRBF-FH1
$36.25
+GST
Delphi Aptiv 630 Metri-pack Blade Fuse Holder ATC/ATO - Connector-Tech ALS
Delphi Aptiv 630 Metri-pack Blade Fuse Holder ATC/ATO
Aptiv (Delphi)
MPN : WSBFH
$9.31
+GST
ATM/APM Mini Blade Fuse Holder Inline 2A-30A 12AWG 3.3mm2 - Connector-Tech ALS
ATM/APM Mini Blade Fuse Holder Inline 2A-30A 12AWG 3.3mm2
Ionnic
MPN : FH14
$5.25
+GST
ATC/ATO Blade Fuse Tap 10A 4mm/1.84mm2 - Connector-Tech ALS
ATC/ATO Blade Fuse Tap 10A 4mm/1.84mm2
Ionnic
MPN : FH10
$6.87
+GST
Bussmann MRBF Marine Fuse Holder 2x 8mm Stud with Cover - Connector-Tech ALS
Bussmann MRBF Marine Fuse Holder 2x 8mm Stud with Cover
Bussmann
MPN : MRBF-FH2
$49.13
+GST
Bussmann AMG MEGA Fuse Holder Panel TPE Rubber 40-500A
Bussmann
MPN : AMGFH1
$28.52
+GST
Sold Out
Delphi Aptiv 280 Metri-pack Blade Fuse Holder ATM - Connector-Tech ALS
Delphi Aptiv 280 Metri-pack Blade Fuse Holder ATM
Aptiv (Delphi)
MPN : MSBFH
$15.82
+GST
Bussmann PFM Suits 2x Mini Fuse Link MFL 1xM8 2xM6 Stud 2x 60A IP66 with Cover - Connector-Tech ALS
Bussmann PFM MFL Fuse Holder 1xM8 2xM6 Stud 2x 20-60A Fuses IP66 with Cover
Bussmann
MPN : 37701-1NN0011
$40.36
+GST
Sold Out
Littelfuse Blade Fuse Block ATO/ATC 12 Way Negative Bus and Cover - Connector-Tech ALS
Littelfuse Blade Fuse Block ATO/ATC 12 Way Negative Bus and Cover
Littelfuse
MPN : 880066
$181.44
+GST
Bussmann LMG 3x AMG Bussed Fuse Module 300A Max
Bussmann LMG 3x AMG Bussed Fuse Module 300A Max
Bussmann
MPN : LMG3-1-001
$74.11
+GST
Bussmann LMG 2x AMG Bussed Fuse Module 300A Max
Bussmann
MPN : LMG2-1-001
$61.75
+GST
Sold Out
Littelfuse SN MEGA Fuse Holder IP66/P69K M8 500A
Littelfuse SN MEGA Fuse Holder IP66/P69K M8 500A
Littelfuse
MPN : 880014
Bussmann PFM Busbar for 3x PFM Modules with Covers
Bussmann
MPN : 3771BUS-3
Bussmann PFM Busbar for 2x PFM Modules with Covers
Bussmann
MPN : 3771BUS-2
$11.88
+GST
Bussmann MEC Suits 2x Micro 280 Relays/4x ATM Fuses IP66 with Long Cover and Bracket
Bussmann
MPN : CFH-A-L-S
Bussmann MEC Suits 4x ATM Fuses IP66 with Short Cover and Bracket
Bussmann
MPN : CFH-A-S-S
Bussmann PDM 60-Position Seats Micro 280 Relays/ATM Fuses 30A IP66 with Cover
Bussmann
MPN : 15310-2-2
Bussmann PDM Seats 5x Micro 280 Relays 10x ATM Fuses 80A IP66 with Cover
Bussmann
MPN : 15304-2-6-4

When ordering a connector it is not always as simple matter of determining between 'male' and 'female' because this can refer to both the housing gender and the contact gender. Many manufacturers offer a given housing gender with both pin and socket. A common example of such confusion occurs in the Deutsch Industrial DT range, where the plug (or male connector) actually contains socket (or female) contacts. For this reason please specify both the contact and housing gender at the time of order.

The IP Rating of a connector or accessory relates to the degree of ingress protection provided by that component. The first digit of the code relates to the degree of protection against access to hazardous parts (conductors etc) and against solid foreign objects. The second digit refers to the degree of protection against the ingress of water. For two examples of this system, consider the most commonly seen IP ratings in our products: IP44 and IP67. IP44 4: Protection from solid objects ≤1mm | 4: Protection against splashing water IP67 6: Protection from dust-sized objects | 7: Protection against immersion in water at depth of 1m for 30mins A complete guide to all IP Ratings is available here.

These terms are used by Phase 3 and ITT Veam on their high-current connectors.The source is considered the half of the connection from which the power is sourced; or the half supplying the electrical power. In an emergency power application, the generator is the source and would be fitted with Panel Source (panel-mount) connectors, a Panel Source Powersafe Box, or Line Source (inline) connectors on pigtails. The drain is the half of the connection which drains the power from the source. In the same emergency power application described above, the network receiving the emergency power supply is the drain and would be fitted with Line Drain connectors, Panel Drain connectors or a Panel Drain Powersafe Box.

We commonly deal with both American Wire Gauge (AWG) and square millimetre (mm2) dimensions as the units used by manufacturers can vary. To convert between measurements please refer this conversion chart.